Testing Laboratory
Auckland Te Toka Tumai | Auckland HospitalDepartment
Chemical Pathology
Delphic Registration Code (Alpha Code)
VITE
Test Code (Numeric Code)
0990
Laboratory Handling
Transport
2-8°C within 24 hours
-20°C more than 24 hours
Registration
Group code for Vitamin A and E: VADE (3162)
Laboratory
LabPLUS High Performance Liquid Chromatography
Sample Stability
Samples are stable for at least two weeks at -20°C.
Associated Tests
Synonyms
alpha-Tocopherol, Tocopherol, Vit E, Vitamin E
Turnaround Time
1 week
Performed Weekly
This test may be vetted by the laboratory. Please include relevant clinical information on the request form to ensure appropriate tests are approved. See the 'Clinical Information' section below for more information on the indications for testing.
Specimen Type
- Plasma
- Serum
Specimen Requirements
Tube/Container Type:
Preferred
- Lithium Heparin - Non-gel (Green Cap)
- Plain (Red Top)
Preferred Sample Volume (ml)
4
Minimum Sample Volume (ml)
1
Paediatric Specimen Requirements
Tube/Container Type:
Preferred
- Plain(Microtainer)
Preferred Sample Volume (ml)
1
Additional Specimen Information
Specimens no longer need protecting from the light.
Plasma collected in EDTA, oxalate or citrate is unsuitable.
SST/PST tubes are acceptable, but non-gel tube serum is preferred.
Can be measured simultaneously with Vitamin A on the same specimen.
Last updated: 24/09/2026