Pyruvate (Blood)

Testing Laboratory

Auckland Te Toka Tumai | Auckland Hospital

Department

Chemical Pathology

Delphic Registration Code (Alpha Code)

BPYR

Test Code (Numeric Code)

0178

Laboratory Handling

Phlebotomy

Arterial blood is acceptable but not capillary.

Transport

Only applies to samples collected at AKH. Send on ice within 5 minutes to the laboratory. Please phone LabPLUS to give advance warning that sample is being sent. As pyruvate is unstable, falsely low levels may be seen if samples do not reach the laboratory on ice, within 5 minutes of sampling.

Laboratory

LabPLUS Special Techniques

Sample Stability

Whole blood samples must be deproteinised within 5 minutes of receipt in laboratory, and stored at 2-8°C.

Synonyms

Pyruvate - blood

Turnaround Time

1 week

Performed as required

Specimen Type

  • Whole Blood

Specimen Requirements

Tube/Container Type:

Preferred
  • Lithium Heparin - Non-gel (Green Cap)
Preferred Sample Volume (ml)

4

Paediatric Specimen Requirements

Tube/Container Type:

Preferred
  • Heparin (Microtainer)
  • Please refer to Additional Information below
Minimum Sample Volume (ml)

1

Additional Specimen Information

2 x paediatric micro-heparin tubes are required.