Platelet Count (Citrate Tube)

Department

Haematology

Delphic Registration Code (Alpha Code)

PLT, FBC, CIT

Test Code (Numeric Code)

1198

Laboratory Handling

Phlebotomy

Collect Citrate tube (Light Blue) top and EDTA tube (Purple) top. In patients where EDTA mediated platelet clumping has been reported, an accurate count can be obtained by collecting a 4 mL citrate tube (blue top). Label **"DO NOT SPIN"**. Tube must be filled up to the "Fill Line"

Separating

Do not spin

Sample Stability

7 days

Associated Tests

Synonyms

Platelet Count (Citrate Tube)

Turnaround Time

1 hour

Specimen Type

  • Whole Blood

Specimen Requirements

Tube/Container Type:

Preferred
  • Citrate (Light Blue Cap)
  • EDTA (Lavender Cap)
Preferred Sample Volume (ml)

2.7

Paediatric Specimen Requirements

Tube/Container Type:

Preferred
  • Citrate (Light Blue Cap)
  • EDTA (Lavender Cap)
Minimum Sample Volume (ml)

1