Testing Laboratories
Northland Te Tai Tokerau | Whangarei Base HospitalNorthland Te Tai Tokerau | Bay of Islands Hospital
Northland Te Tai Tokerau | Dargaville Hospital
Northland Te Tai Tokerau | Kaitaia Hospital
Department
Haematology
Delphic Registration Code (Alpha Code)
HS1
Test Code (Numeric Code)
1731
Laboratory Handling
Phlebotomy
Tube must be adequately filled.
Sample Stability
APPT (non-heparin) 12 hours INR/PR, FIB, TCT, Dimer 24 hours
Associated Tests
Synonyms
Coagulation screen
Coag panel
Haemostasis screen
Basic screen
Turnaround Time
1 day
Specimen Type
- Plasma
Specimen Requirements
Tube/Container Type:
Preferred
- Citrate (Blue Cap)
Acceptable
- Citrate (Light Blue Cap)
Preferred Sample Volume (ml)
2.7
Minimum Sample Volume (ml)
1.8
No of Samples Required
1
Paediatric Specimen Requirements
Tube/Container Type:
Preferred
- Citrate (Light Blue Cap)
Acceptable
- Citrate (Microtainer)
Pre-testing Requirements
Provide the clinical indication and relevant clinical details, including current/recent anticoagulant therapy. Anticoagulant status is important for test selection, reflex testing and interpretation.
Last updated: 12/11/2026