Adenovirus PCR

Testing Laboratory

Auckland Te Toka Tumai | Auckland Hospital

Department

Virology

Delphic Registration Code (Alpha Code)

ADPC

Test Code (Numeric Code)

8053

Laboratory Handling

Transport

Room temperature (RT): same-day transport at RT is acceptable.

Registration

Eye sample for Adenovirus samples register for EPAN. Respiratory samples for Adenovirus PCR register for RPAN. Blood , Tissue and other body fluids register for ADPC.

Separating

Unspun EDTA whole blood

Laboratory

EDTA whole blood, Biopsies, and other fluid specimens: should be sent to the Molecular Infectious Diseases section at ambient temperature on the day of collection during normal working hours, Monday to Friday (08:00–16:00). After hours and on weekends, specimens should be stored at 2–8°C in the designated box/rack in ALSS.

Sample Stability

EDTA whole blood: Stable at room temperature for up to 24 hours and at 2–8°C for up to 7 days. Biopsies, and other body fluids: Stable at room temperature for up to 24 hours and at 2–8°C for up to 7 days.

Synonyms

Adenovirus PCR

Turnaround Time

3 days

Specimen Type

  • Bronchial Washing
  • Eye Swab
  • Nasopharyngeal Swab
  • Sputum
  • Tissue
  • Tracheal Aspirate
  • Urine

Specimen Requirements

Tube/Container Type:

Preferred
  • EDTA (Lavender Cap)
Acceptable
  • Please refer to Additional Information below

Paediatric Specimen Requirements

Tube/Container Type:

Preferred
  • EDTA (Microtainer)
Acceptable
  • Please refer to Additional Information below

Additional Specimen Information

Sample requirements:
Unspun EDTA whole blood 2 mL. Absolute minimum is 0.5 mL
Body fluids- 1mL
Fresh tissue: submit in sterile normal saline.
Formalin-fixed paraffin-embedded (FFPE/PET) tissue block.

Last updated: 29/08/2026