ADAMTS-13 Activity with Inhibitor Screen (Blood)

Testing Laboratory

Auckland Te Toka Tumai | Auckland Hospital

Department

Haematology

Delphic Registration Code (Alpha Code)

TS13

Test Code (Numeric Code)

1365

Laboratory Handling

Phlebotomy

  • Collect 1 x 2.7ml Citrate (Blue Cap).
  • Paediatric: collect 2 x 1ml Citrate microtainer.
  • EDTA destroys ADAMTS-13 activity, so it is important to collect/fill citrate specimen(s) before EDTA specimens to avoid EDTA contamination.
  • Collection tubes must be adequately filled.

    Transport

    Hand deliver transparent/clear top Citrate tubes to Coagulation section - DO NOT PLACE ON 8100.

    Sample Stability

    Ambient (8-24°C) 8-hours
    2-8°C 24-48 hours
    -20°C6-months

  • Synonyms

    ADAMTS-13 Level
    ADAMTS-13

    Turnaround Time

    3 days

    Requests for ADAMTS-13 activity must be arranged through a LabPlus Haematologist who will also advise when results will be available. Please note the assay takes 5 hours to complete.

    This test may be vetted by the laboratory. Please include relevant clinical information on the request form to ensure appropriate tests are approved. See the 'Clinical Information' section below for more information on the indications for testing.

    Specimen Type

    • Whole Blood

    Specimen Requirements

    Tube/Container Type:

    Preferred
    • Citrate (Blue Cap)
    Preferred Sample Volume (ml)

    2.7

    No of Samples Required

    1

    Paediatric Specimen Requirements

    Tube/Container Type:

    Preferred
    • Citrate (Microtainer)
    • Please refer to Additional Information below
    Minimum Sample Volume (ml)

    2

    Pre-testing Requirements

    Requests for this test must be arranged by contacting a LabPLUS Haematologist.
    Requests must be accompanied by the CC7719 ADAMTS13 Request Form or it will not be processed.
    CC7719 ADAMTS13 Request Form Link
    Please provide requestor contact phone details on the request form.

    Additional Specimen Information

    Paediatric: collect 2 x 1ml Citrate microtainer.
    1. EDTA destroys ADAMTS-13 activity, so it is important to collect/fill citrate specimen(s) before EDTA specimens to avoid EDTA contamination.
    2. Collection tubes must be adequately filled.

    Last updated: 18/08/2026